Patient Monitor NC10
Item #: AM-COR-0174-ZP
Model: NC10
Regulatory Status: Approved by Regulations on the Supervision and Administration of Medical Devices.
Application: Medical Use
Features: Flexible modular design, comprehensive monitoring options
The new NC series semi-plug-in monitors provide you with the most commonly used important parameters, including ECG, NIBP, SpO2, RESP, dual TEMP and dual IBP. At the same time, the plug-in structure design for you can be equipped with high-end monitoring parameter modules, convenient You can flexibly add parameter modules according to specific clinical needs, and the modules that can be used can be replaced, which will enable you to achieve efficient use in the clinic.
Pursuing rigorous testing
We use a professional test method to conduct a comprehensive functional test of the system, covering software, hardware and parameter specifications. In terms of software functions, we constantly update test cases to further improve
Ground test, to achieve the stability of clinical use; In terms of hardware functions, in up to hundreds of thousands of ground tests, U disk, SD card, serial port, real-time clock, etc.
Working interface connection status. Parameter specifications are tested in strict accordance with our technical requirements.
We placed 45 instruments in a high-temperature aging room for testing. Each prototype is placed in a high-temperature (50 ° C) aging room for not less than 30 days, and the test of the switch is not less than 10,000 times.
The internal temperature of the device and the temperature, function, and parameter stability of key components are tested to improve the measurement accuracy of the product under the specified 0 ~ 40 ℃ operating environment.
For battery testing, our hardware engineers focus on the battery software protocol, charge and discharge time, over-current and over-voltage protection, internal temperature rise, and safety factor during the self-test process. Charge for 100 batteries
Discharge cycle test can reach no less than 300 charge and discharge cycles. At the same time, the batteries we use have passed IEC62133: 2012 certification.
In order to ensure the number of plug-in modules in the clinic, we perform manual plug-in tests on the plug-in modules. Through structural improvement, we have completed up to 10,000 plug-in operations without structural looseness.
It can realize long-term use of the module.
At the same time, the NC series of semi-plug-in monitors have been tested by professional testing institutions for low temperature testing (-40 ° C), high temperature testing 45 ° C, rapid temperature change testing (between 40 ° C and 75 ° C), sinusoidal vibration
Both tests and crash tests show stable performance.
Supports wireless or wired networking
Support the observation function of other bed, convenient for medical staff to monitor patients in real time
Fanless design, reducing secondary pollution of laminar flow, quieter without noise
Support external laser printer, A4 paper print report, support 12 lead ECG waveform print
48-hour holographic waveform review and monitoring data record playback review function
Standard 2200mAh lithium battery with long battery life
VG55 Non-invasive Ventilator, Aeonmed, povide ICU-level non-...
Add to cartAntu fully automatic blood culture system uses advanced non-...
Add to cartAs a professional supplier of medical devices, STEMart-PPE is good at listening, digging and uncovering the unique demands of our customers and committed to providing tailored solutions and products across the continuum of care. Through the power of science, we bring improvement to large healthcare systems, independent physician practices and daily life of home health patients and their families.