Pressure steam high pressure Sterilizer MOST-L
  • Pressure steam high pressure Sterilizer MOST-L
Pressure steam high pressure Sterilizer MOST-L

Pressure steam high pressure Sterilizer MOST-L

Item #: AM-COR-046-WTT

Model: MOST-L

Regulatory Status: Approved by Regulations on the Supervision and Administration of Medical Devices.

Add to cart

Product Details

Application: Medical Use

Features: ♦ Clamshell automatic door structure

    L60 / 80-DP sterilizer door structure adopts multi-point synchronous linkage pressing technology to make the door seal more reliable. One-touch door opening, automatic control, fast and labor-saving.

  ♦ Humanized operating system

    Microcomputer automatic control, LCD text display, inductive keys, can intuitively observe equipment information parameters, sterilization process information, simple and convenient operation, automatic control of sterilization process.

  ♦ Built-in water tank structure

    Storage equipment water can realize the internal circulation of water vapor without the need to add water to the water tank every time the program is run. At the same time, the equipment is equipped with a standard 5L gas cylinder to ensure the internal circulation of water vapor and no steam discharge.

  ♦ Water quality detection function

    The water quality of the water tank can be detected, and the system will prompt when the water quality does not meet the requirements.

  ♦ Rich program types

    There are three types of laboratory procedures, medical procedures and custom procedures, with a total of 108 procedures. It contains 8 preset programs and 100 custom programs. Laboratory procedures include stationary, fixed waste, culture medium, liquid, agar procedures; medical procedures include bare procedures, packaging procedures, rubber procedures;

   ♦ Flexible exhaust control

    The exhaust valve opening temperature can be set: after the sterilization is completed, the user can adjust the control parameters according to the actual needs to achieve the flexible opening of the exhaust valve of the equipment to meet different process requirements.

    Exhaust mode: Control the steam discharge speed by changing parameters, and realize three types of exhaust modes: fast exhaust, slow exhaust, and non-exhaust.

   ♦ Steam-free effluent throughout the process

    The equipment has a built-in condensing system to cool the water vapor discharged from the sterilization chamber. It can handle different types of programs. By adjusting parameters, there are steam exhaust methods such as fast exhaust, slow exhaust, and no exhaust. The generation of aerosols and the occurrence of laboratory injuries ensure biological safety.

   ♦ Safety Interlock

    Over-temperature automatic protection device: When the temperature of the pot exceeds the set temperature, the system automatically cuts off the heating voltage and displays an alarm.

    Anti-dry-burn dual protection device: low water level detection, the system automatically cuts off the heating voltage and alarms below the specified water level; the anti-dry-burn temperature controller can trigger an alarm and cut off the heating if the signal detection fails.

    Door safety interlocking device: The electronic door lock can only be started when the door is closed and the sterilization program can be started to heat up; the internal chamber is under pressure or voltage is not turned on and the door opening mechanism is locked and the door cannot be opened.

    Overpressure automatic pressure relief safety valve: the pressure in the inner chamber reaches the opening pressure of the safety valve, the safety valve automatically opens the pressure relief, and automatically ensures the equipment to operate safely.

    Electronic circuit safety device: AC main circuit with safety protector, quality control circuit with overvoltage and overload protection.

    Leakage protection device: The equipment is equipped with a leakage protector. When a leakage occurs, the equipment can automatically cut off the power to protect the safety of the operator.

    Cooling lock: The liquid in the inner chamber exceeds the safe temperature, and the door cannot be opened to ensure the safety of personnel and items, to avoid the risk of liquid splashing or even bursting the bottle.

MOST-L steam sterilizer laboratory series, mainly for various types of university laboratories, pharmaceutical factory laboratories, inspection departments, disease control centers and other institutions, for medical health, scientific research and other units for medical devices, laboratory utensils, culture Sterilization of liquids and preparations, materials that may come in contact with blood or body fluids.

Related products


VG55 Non-invasive Ventilator

VG55 Non-invasive Ventilator, Aeonmed, povide ICU-level non-...

Add to cart

BC120 automated blood culture system

Antu fully automatic blood culture system uses advanced non-...

Add to cart

As a professional supplier of medical devices, STEMart-PPE is good at listening, digging and uncovering the unique demands of our customers and committed to providing tailored solutions and products across the continuum of care. Through the power of science, we bring improvement to large healthcare systems, independent physician practices and daily life of home health patients and their families.

Contact us

Privacy Policy   |   Cookie Policy   |   © 2024 STEMart-PPE. All rights reserved.
Shopping Cart 0